I, as purchaser and/or end user of a booster pump and/or related accessories (“the Product”), expressly ASSUME ALL RISKS OF INJURY, DEATH OR DAMAGE to my person or property arising from or in conjunction with my purchase, use or misuse of the Product. I understand and am fully aware that there are many inherent risks and hazards associated with the operation of high-pressure gas booster pumps, including but not limited to: high pressure hazards – failure of hoses, fittings or the pump body can lead to catastrophic mechanical failure and high-velocity projectiles; oxygen hazards – handling oxygen or nitrox involves a high risk of fire, rapid combustion or explosion; gas toxicity – improper blending or contamination of breathing gases can lead to hyperoxia, hypoxia, hypercapnia, narcosis or decompression sickness; and physical injury – serious injury or death resulting from explosion, fire or mechanical impact. I fully understand and accept that, by using the Product, I may be seriously injured or killed, even if I do nothing wrong. I represent and warrant that I am a certified scuba diver or technician with specialized training in gas blending and handling of high-pressure gases. I have read and understand the manufacturer’s operating instructions and all safety protocols. I understand that any unauthorized modifications, use of non-original parts, or failure to follow service intervals voids any applicable warranties and significantly increases the risk of catastrophic failure. I voluntarily release, discharge, waive and relinquish any and all actions, claims or causes of action for injuries, damages or death arising out of my purchase, use or misuse of the Product based upon any negligent act or omission of the Released Parties, nor any of their officers, directors, instructors, agents, employees, contractors or assigns including, but not limited to, the design, materials, assembly, performance, warnings, instructions for use or operation of the Product. I UNDERSTAND AND AGREE that Released Parties shall not be held liable or responsible in any way for any injury, death or other damages to me, my family, estate, heirs or assigns arising out of my purchase, use or misuse of the Product.
Description

USUN GB40-OL Booster Pump by USUN

SKU:

USUN GB40-OL Booster Pump: Efficient Gas Management for Tech Divers

Every technical diver knows the frustration of having plenty of oxygen or helium left in a storage cylinder, but not enough pressure to get a good fill for a deco bottle or rebreather tank. The USUN GB40-OL Booster Pump solves this problem, allowing you to pull that expensive gas down low and boost it to the pressure you need. This unit creates a cost-effective solution for managing your gas logistics safely and efficiently.

Ideal for Smaller Cylinders 

This is a Single Action booster, designed specifically for precision and smaller volumes. While it is capable of filling up to an AL80 (11.1 liters), it truly shines when filling cylinders smaller than 40 cubic feet (approx. 5.7 liters). This makes it the perfect workhorse for topping off rebreather oxygen and diluent tanks, or filling shallow decompression bottles without wasting gas.

Safety First 

Working with high-pressure oxygen requires strict safety protocols. This booster arrives oxygen cleaned and ready for service. Because it is air-driven, it requires zero electrical connections. This eliminates the risk of heat, flames, or sparks during operation, giving you peace of mind when blending volatile mixes.

Low Maintenance, Long Life 

You want to spend time diving, not servicing your pump. The USUN seal system is designed for a long working life and requires no airline lubrication. This keeps your gas path clean and reduces maintenance downtime. The unit is robust enough to handle continuous stop-and-start applications, so you can check pressures and switch tanks without worrying about the booster stalling or overheating.

Drive Gas Requirements 

You can power this booster using a shop compressor or compressed gas from scuba cylinders. While the manufacturer lists a high requirement of 28 cfm for rapid cycling, we prioritize safety and heat management. Our clients successfully run this booster with compressors delivering 6 to 10 cfm, resulting in a slower, cooler, and safer fill rate.

  • Pro Tip: In our experience, using one standard AL80 cylinder to drive the booster will typically boost about 40 cubic feet of gas. Keep in mind that your results may vary depending on your starting and ending pressures.

System Customization 

Please note that this booster ships without hoses or fittings. However, we are here to help. If you need assistance building a complete system with the correct whips, gauges, and connections for your specific setup, just reach out to us.

Stop wasting helium and oxygen. Optimize your fill station and order the USUN GB40-OL Booster Pump today!

Features
  • Single Action Efficiency: Optimized for filling smaller cylinders like rebreather tanks and deco bottles (less than 40 cu/ft).
  • Spark-Free Operation: Air-driven design requires no electricity, eliminating heat and spark risks associated with electric motors.
  • Lubrication-Free: The seal system operates without airline lubrication, preventing contamination of the gas path.
  • Variable Speed Control: Allows the user to infinitely adjust cycling speed and output for safe, controlled blending.
  • Robust Durability: Designed to handle continuous stop/start cycles without adverse effects on the mechanism.
  • Gas Compatibility: Suitable for boosting Oxygen, Helium, Air, and Argon.
  • Compact Footprint: Small size makes it easy to integrate into existing fill stations or transport if necessary.
Specs
  • Brand: USUN
  • Model: GB40-OL
  • Type: Single Action Booster
  • Dimensions: 19.7 x 12.6 x 12.6 inches (50cm x 32cm x 32cm)
  • Pressure Ratio: 40:1
  • Cleanliness: Oxygen Cleaned
  • High-Pressure Piston Rod: 25mm (approx. 1 inch)
  • Minimum Inlet Pressure: 25 bar (approx. 362 psi)
  • Maximum Outlet Pressure: 320 bar (approx. 4,641 psi)
  • Maximum Drive Gas Pressure: 8 bar (approx. 116 psi)
  • Outlet Pressure Formula: 40PA
  • Inlet Port Size: 1/4" NPT
  • Outlet Port Size: 1/4" NPT
  • Drive Gas Usage (Estimated): (1) AL80 drive cylinder boosts approx. 40 cu/ft of gas
Comparison Chart
USUN GB40-OL Booster Pump Comparison Chart
Reviews
Product Q&A

Easy Returns

60-Day Hassle-Free Returns

Not the perfect fit? No problem. We offer a 100% credit or refund on any item returned within 60 days, as long as it's in new, unused condition with its original packaging. We want you to be happy with your gear, period.

Click here for more info

100% Secure Shopping

Order With Confidence

Your security is our top priority. We use the latest encryption technology to ensure your personal information is 100% safe, so you can shop with total peace of mind. Not comfortable ordering online? Give us a call at (815) 267-8400 and we'll gladly help you over the phone.

Full Manufacturer's Warranty

Authorized Retailer for USUN

We are an Authorized Dealer for every single brand we sell. This means you are getting 100% authentic gear, and your purchase is fully protected by the manufacturer's warranty. No gray-market gear, no warranty worries. We've got your back.

Our Promise to You

We\’re Divers, Just Like You

Our promise is that you get the right gear, and that it's right the first time. As divers ourselves, we'll help you find the perfect fit for your style of diving. Then, we'll quality-inspect your order before it ships to ensure it's ready for your next adventure. We're your local dive shop, no matter where you are.